# Code of openBIS instance instance-code = # The root directory of the data store storeroot-dir = data/store # The check interval (in seconds) check-interval = 60 # The time-out for clean up work in the shutdown sequence (in seconds). # Note that that the maximal time for the shutdown sequence to complete can be as large # as twice this time. shutdown-timeout = 30 # If free disk space goes below value defined here, a notification email will be sent. # Value must be specified in kilobytes (1048576 = 1024 * 1024 = 1GB). If no high water mark is # specified or if value is negative, the system will not be watching. highwater-mark = 1048576 # If a data set is successfully registered it sends out an email to the registrator. # If this property is not specified, no email is sent to the registrator. This property # does not affect the mails which are sent, when the data set could not be registered. notify-successful-registration = false # The URL of the openBIS server server-url = https://localhost:8443/openbis # The username to use when contacting the openBIS server username = etlserver # The password to use when contacting the openBIS server password = # SMTP properties (must start with 'mail' to be considered). # mail.smtp.host = localhost # mail.from = etlserver@localhost # Maximum number of retries if renaming failed. # renaming.failure.max-retries = 12 # The number of milliseconds to wait before retrying to execute the renaming process. # renaming.failure.millis-to-sleep = 5000 # Globally used separator character which separates entities in a data set file name date-set-file-name-entity-separator = _ # Prefixes for processing paths for all procedure types. # default-prefix-for-absolute-paths is the key for paths starting with '/'. # default-prefix-for-relative-paths is the key for paths not starting with '/'. # default-prefix-for-absolute-paths = # Processors of processing instructions. # # processors: comma separated list of procedure type codes # processor..prefix-for-absolute-paths: Key for a processing path starting with '/'. # processor..prefix-for-relative-paths: Key for a processing path not starting with '/'. # processor..parameters-file: Name of the file containing the processing parameters. # processor..finished-file-template: Name of the marker file which finishes processing. processors = DATA_ACQUISITION processor.DATA_ACQUISITION.prefix-for-absolute-paths = ${default-prefix-for-absolute-paths} processor.DATA_ACQUISITION.prefix-for-relative-paths = targets/processing processor.DATA_ACQUISITION.parameters-file = parameters processor.DATA_ACQUISITION.data-set-code-prefix-glue = ${date-set-file-name-entity-separator} processor.DATA_ACQUISITION.finished-file-template = .MARKER_is_finished_{0} # Can be one of PROPRIETARY (the data as acquired from the measurement device) # or BDS_DIRECTORY (the data in BDS format in a directory container). processor.DATA_ACQUISITION.input-storage-format = PROPRIETARY # time after which the copy of a single file for processing should complete. # If that will not happen, operation will be terminated and relaunched. processor.DATA_ACQUISITION.data-copy-timeout = 10 # Comma separated names of processing threads. Each thread should have configuration properties prefixed with its name. # E.g. 'code-extractor' property for the thread 'my-etl' should be specified as 'my-etl.code-extractor' inputs=main-thread # --------------------------------------------------------------------------- # 'main-thread' thread configuration # --------------------------------------------------------------------------- # The directory to watch for incoming data. main-thread.incoming-dir = data/incoming # ---------------- Plugin properties # The extractor class to use for code extraction main-thread.data-set-info-extractor = ch.systemsx.cisd.etlserver.DefaultDataSetInfoExtractor # Separator used to extract the barcode in the data set file name main-thread.data-set-info-extractor.entity-separator = ${date-set-file-name-entity-separator} # The extractor class to use for type extraction main-thread.type-extractor = ch.systemsx.cisd.etlserver.SimpleTypeExtractor main-thread.type-extractor.file-format-type = TIFF main-thread.type-extractor.locator-type = RELATIVE_LOCATION main-thread.type-extractor.observable-type = HCS_IMAGE main-thread.type-extractor.procedure-type = DATA_ACQUISITION # The storage processor (IStorageProcessor implementation) main-thread.storage-processor = ch.systemsx.cisd.etlserver.DefaultStorageProcessor # main-thread.storage-processor = ch.systemsx.cisd.etlserver.BDSStorageProcessor # main-thread.storage-processor.version = 1.0 # main-thread.storage-processor.sampleTypeCode = CELL_PLATE # main-thread.storage-processor.sampleTypeDescription = Screening Plate # main-thread.storage-processor.format = UNKNOWN V1.0